Qlogic QLogic 12000 Series Guida di Installazione Pagina 100

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 114
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 99
D–FRU Replacement
QLogic 12300
D-2 D000102-000 B
3. Connect Ethernet and Serial cables.
4. Connect AC power.
5. If applicable, change the switch, gateway and subnet mask addresses to a
new network address.
6. Cable all applicable IB ports.
QLogic 12300
Chassis Replacement
FRU part number:12300-BS01-9X
Removal Procedures
1. Power down the switch by unplugging AC power.
2. Remove all applicable IB, Ethernet and Serial cables. Set these aside for
reinstalling the replacement switch.
3. Remove the switch from the rack. Keep all rail hardware installed in the rack.
4. Remove the hat rails from the switch. Set these aside for reinstalling the
replacement switch.
Replacement Procedures
1. Install the hat rails to the switch.
2. Rack mount the switch in the existing rails on the rack.
3. Connect Ethernet and Serial cables.
4. Connect AC power.
5. Change the switch, gateway and subnet mask addresses to a new network
address.
6. Cable all applicable IB ports.
Fan/Power Supply Replacement
FRU part number:12300-PS01-9X
Removal Procedures
1. Push the finger tab to the right.
Vedere la pagina 99